Potterton E50 Error: Understanding the Hot Water Thermistor Fault

Disclaimer

The information provided on this page is intended for general knowledge and troubleshooting purposes only. We at 0800 Homefix do not recommend attempting to fix boiler issues yourself, as this can lead to further damage or pose significant safety risks. Always seek the assistance of a qualified and Gas Safe registered engineer for any repairs or maintenance on your heating system. 0800 Homefix is not responsible for any actions taken by individuals based on the information provided here.

The Potterton E50 error is a significant boiler error code that indicates an issue with the hot water thermistor or the domestic hot water (DHW) sensor. This fault can disrupt the boiler’s ability to provide consistent heating and hot water, which is critical for everyday comfort. Recognizing and understanding this error can help homeowners take the right steps to address the issue promptly and efficiently.

Understanding Potterton E50 Error Codes

Potterton E50 error codes are designed to alert users to specific issues within the boiler system. These error codes are essential for diagnosing and resolving problems that may affect the boiler’s performance. In the case of the E50 error, the issue typically revolves around the negative temperature coefficient (NTC) thermistor, which is responsible for monitoring and regulating water temperature within the boiler.

Common Potterton Boiler Error Codes

The Potterton E50 error is just one of many system boiler error codes that can appear. Here are some other Potterton boiler error codes and their meanings:

  • E20: Water pressure fault, which could indicate a drop in primary system water pressure.

  • E30: Fan fault, often linked to issues with the gas valve or flue thermostat sensor.

  • E33: Flame detection fault, which might suggest a false flame or gas supply issue.

Understanding these codes helps in pinpointing specific faults within the boiler, allowing for targeted troubleshooting and repair.

Troubleshooting the Potterton E50 Fault

When dealing with the Potterton E50 error, several key areas should be checked, including the DHW NTC sensor, wiring faults, and potential primary water circulation faults.

DHW NTC Sensor Fault Diagnosis

A common cause of the E50 error is a fault with the Domestic Hot Water (DHW) NTC sensor. This sensor plays a crucial role in monitoring the water temperature and ensuring the boiler operates efficiently. If this sensor fails, it can trigger an error code that disrupts the hot water supply.

To diagnose a DHW NTC sensor fault:

  1. Inspect the sensor and its connections for visible damage or loose wiring.

  2. Use a multimeter to check the resistance of the NTC sensor, ensuring it falls within the manufacturer’s specifications.

  3. If the sensor is faulty, replacing it is necessary to restore proper boiler function.

Resolving Heating Thermistor Sensor Faults

The heating thermistor sensor is another component that can cause issues when faulty. This sensor helps regulate the boiler’s operating temperature, and any malfunctions can lead to an error code like the E50.

To resolve a heating thermistor sensor fault:

  • Inspect the heating flow switch for errors, which could indicate a heating flow switch error.

  • Check for any wiring faults that might be affecting the sensor’s operation.

  • Test the sensor’s resistance using a multimeter, and replace it if the readings are outside the acceptable range.

Addressing Primary Water Circulation Faults

Primary water circulation faults can also trigger the E50 error. These faults are often caused by a probable pump jammed condition or air trapped within the system.

To address these faults:

  • Check the circulation pump for any signs of failure or blockage.

  • Bleed the radiators to remove any trapped air that might be causing circulation issues.

  • Inspect the differential water flow switch for proper operation, as a faulty switch can prevent adequate water circulation.

 

Technical Specifications and External Factors

The performance of the Potterton E50 can also be influenced by external factors such as gas supply issues and environmental conditions.

Gas Supply and Boiler Fault Interrelation

A proper gas supply is vital for the Potterton E50 to function correctly. Any interruptions or faults in the gas supply can lead to various boiler error codes related to the gas valve or system pressure.

To ensure the gas supply is functioning properly:

  • Inspect the gas valve for any blockages or malfunctions.

  • Check the system pressure regularly to ensure it stays within the recommended range.

Environmental Impact on Potterton E50 Performance

External conditions such as cold weather can affect the boiler’s performance. A frozen condensate pipe is a common issue in colder climates, which can lead to drainage problems and trigger an error code.

To mitigate environmental impacts:

  • Insulate the boiler condensate pipe to prevent freezing.

  • Ensure the boiler is receiving the correct power supply, as a wrong power supply Hz can affect its performance.

Professional Assistance and Maintenance Tips

For complex issues like the Potterton E50 error, it’s crucial to seek help from a Gas Safe registered engineer. Regular maintenance and professional check-ups can help prevent these errors and extend the boiler’s lifespan.

When to Call a Gas Safe Registered Engineer

If the E50 error persists after basic troubleshooting, it’s time to call a Gas Safe registered engineer. Persistent errors, unusual noises, or a repeated thermostat sensor tripped lockout indicate a deeper issue that requires professional attention.

Preventive Measures and Regular Check-ups

To keep your Potterton E50 running smoothly:

  • Schedule annual maintenance to check the room controller, sensors, and other critical components.

  • Regularly monitor the domestic hot water temperature and system pressure.

  • Keep vents clear and ensure nothing obstructs the boiler’s operation.

Frequently Asked Questions

The Potterton E50 error code indicates a fault with the hot water thermistor or the DHW NTC sensor, which affects the boiler’s ability to regulate temperature.

Start by resetting the boiler and inspecting the DHW NTC sensor for damage. If the sensor is faulty, replacing it may be necessary.

Error code 118 typically indicates a flow sensor issue. Conduct a water pressure test and inspect the flow sensor for blockages or damage.

Persistent E50 errors could be due to unresolved issues with the hot water thermistor, wiring faults, or the printed circuit board (PCB).

For more information on common boiler errors and solutions, or to book a service with a qualified engineer, visit our boiler repair page.